e-mail address
password




Register |  Forgot Password
  Modulation Sciences Inc.
12A World's Fair Drive
Somerset, NJ 08873

Phone: 732-302-3090
Fax: 732-302-0206

E-mail:
info@modsci.com

tech_support@modsci.com
sales@modsci.com


Introduction  |  Details  |  Specifications  |   Manuals  |  White Papers

PARAMETERS
   
OVERALL ACCURACY: ±1.0% at 100% modulation for any frequency from 50 Hz to 100 kHz.
   
STATIC SCA ACCURACY: ±1.0% of 100% total.
   
OPERATING TEMPERATURE: 0° to 50° Celsius.
   
FREQUENCY RESPONSE: ±0.5% (±0.043 dB) at 100% modulation, from 50 Hz to 100 kHz.
   
PEAK FLASHER RESPONSE TIME: FCC Mode - 900 microseconds.
Peak Weighted Mode - 200 microseconds, user-adjustable. Strap- selectable to count peak flasher occurrences.
 
ONE MINUTE COUNTER STANDOFF DELAY: FCC Mode – 5 milliseconds.
Peak Weighted Mode – 30 milliseconds.
   
INPUT SENSITIVITY: 0.8 to 5 Volts peak - peak for 75 kHz = 100%modulation.
   
INPUT IMPEDANCE: 10 k Ohms.
 
CONNECTORS
   
COMPOSITE INPUT: BNC.
   
DATA: RS232C, 25 pin "D" connector
   
REMOTE CONTROL INTERFACE: 15 pin "D" connector. DC Voltages.
   
RELAY CONTACTS: 100 mA, 48 Volts resistive load.
 
DC VOLTAGES
   
METERING SIGNALS: 0 to 2.5 Volts, 5 mA maximum, negative common to ground.
   
SOURCE IMPEDANCE: 0 Ohms at DC.
   
ACCURACY: <0.4% linearity error.
   
RF PROTECTION: All inputs and outputs RF suppressed.
   
DIMENSIONS: 1.75" H x 19.0 " W x 10.0 " D.
22.5mm H x 483 mm W x 254 mmD.
   
POWER: 50/60 Hz AC 100-130 VAC, fused for 3-16 A.
200-260 VAC, fused for 1-10 A.
Voltage selector on rear panel.